Jumo 709050 IPC IGBT Power Converter IPC 70A Operating User Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
5 Settings
30 [IGBT Power Converter 70A] 02.08
5.5 Control inputs
The internal switches S8, S9 and S104 are used to adapt the converter to the
available control signal (controller output signal).
The voltage and current inputs are separated from one another. The current
inputs (+,-) are arranged as differential inputs, i.e. they can have a maximum
common mode voltage of 7V with respect to the common ground potential ().
If the current and voltage inputs are used at the same time, their effect will be
cumulative.
k factory setting
Analog
control inputs
The converter can be controlled through the following signals
(continuous power control):
- voltage signal (terminals 3, 4)
- current signal (terminals 1, 2)
-5-k potentiometer (terminals 3, 4, 5)
For this purpose, a 10 V source is provided on terminal 5.
(switch settings are as for a 0 ... 10 V signal)
Control signal Internal switches
Signal start Signal end S8 S9 S104
0 mA 20 mA 0 1 1
4 mA 20 mA 0 0 2
0 V 10 V 0 1 1
2 V 10 V 0 0 2
0 V 5 V 1 1 1
1 V 5 V 1 0 2
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 47 48

Comments to this Manuals

No comments